3 Installation
3.5 Electrical Installation
DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com 65
3.5.1.5 Arrangement and terminal capacity
The arrangement and size of the connection terminals depend on the size of
the power section (FS1, FS2, and FS3 sizes).
3.5.1.6 Stripping lengths
Figure 40: Stripping lengths in the power section
The cross-sectional wire areas that can be connected
and the screws' tightening torques are listed in the annex
( Section 11.11, „Cables and fuses“, page 204).
Mains 1~ Mains 3~ Motor DC-Link, Brake Resistor
PE
A1
PE
A1
PE
A1
PE
A1
Frame
size
A1
[mm] [in]
FS1 8 0.3
FS2
10 0.39
FS3
10 0.39
Mains = Electrical supply system
Motor = Motor connection
DC link = Internal DC link
Brake resistor = Braking chopper