3 Installation
3.6 Electrical Installation
DC1 Variable Frequency Drive 04/16 MN04020003Z-EN www.eaton.com 81
3.6.1.3 Stripping lengths and tightening torques
Figure 43: Stripping lengths in the power section
Mains = Electrical power network (supply voltage)
Motor = Motor connection
DC-Link = DC link coupling
Brake Resistor = Braking resistance (brake chopper)
Table 8: Terminal capacities and tightening torques
Mains 1~ Mains 3~ Motor DC-Link, Brake Resistor
PE
A1
PE
A1
PE
A1
PE
A1
Frame
size
A1 Maximum terminal
capacity
Tightening moment
mm in mm
2
AWG N/m lb-in
FS1 8 0.3 8 8 1 8.85
FS2 10 0.39 8 8 1 8.85
FS3 10 0.39 8 8 1 8.85
FS4 10 - 11 0.39 - 0.43 16 5 2.1 19
PE connection: Ring terminal with a diameter of 6.3
mm (0.25")