EasyManua.ls Logo

Eaton PowerXL DG1 - Table 69. 400 V FR2-20 Hp Efficiency Rating; Table 70. 400 V FR3-40 Hp Efficiency Rating; Table 71. 400 V FR4-75 Hp Efficiency Rating; Table 72. 400 V FR5-150 Hp Efficiency Rating

Eaton PowerXL DG1
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
Appendix B—Installation guidelines
POWERXL SERIES VFD MN040002EN—February 2018 www.eaton.com
Table 69. 400 V FR2-20hp efficiency rating
400 V FR2-20hp
25%Torque 50%Torque 100%To rque
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
10%Speed 0.7 0.572 0.128 18.29% 0.531 81.66% 1.392 1.216 0.176 12.64% 0.708 87.33% 2.414 2.156 0.258 10.69% 0.797 89.31%
50%Speed 2.363 2.227 0.136 5.76% 0.485 94.23% 4.559 4.374 0.185 4.06% 0.727 95.93% 9.182 8.833 0.349 3.80% 0.865 96.20%
90%Speed 3.971 3.819 0.152 3.83% 0.461 96.16% 7.85 7.64 0.21 2.68% 0.708 97.41% 15.482 15.096 0.386 2.49% 0.855 97.51%
100%Speed 4.535 4.386 0.149 3.29% 0.499 96.72% 8.734 8.536 0.198 2.27% 0.74 97.73% 17.303 16.904 0.399 2.31% 0.868 97.69%
ote: N All 10% speed is taken at 5Hz.
Table 70. 400 V FR3-40hp efficiency rating
400 V FR3-40hp
25%Torque 50%Torque 100%To rque
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
10%Speed 1.043 0.858 0.185 17.74% 0.557 82.28% 1.886 1.65 0.236 12.51% 0.73 87.46% 3.629 3.239 0.39 10.75% 0.822 89.26%
50%Speed 4.666 4.451 0.215 4.61% 0.581 95.38% 9.156 8.834 0.322 3.52% 0.793 96.48% 18.174 17.534 0.64 3.52% 0.872 96.49%
90%Speed 8.142 7.9 0.242 2.97% 0.573 97.07% 16.09 15.716 0.374 2.32% 0.785 97.65% 31.707 30.968 0.739 2.33% 0.872 97.67%
100%Speed 8.982 8.742 0.24 2.67% 0.59 97.32% 17.734 17.359 0.375 2.11% 0.794 97.87% 34.785 34.04 0.745 2.14% 0.877 97.86%
ote: N All 10% speed is taken at 5Hz.
Table 71. 400 V FR4-75hp efficiency rating
400 V FR4-75hp
25%Torque 50%Torque 100%To rque
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
10%Speed 1.735 1.426 0.309 17.81% 0.588 82.17% 3.5 3.05 0.45 12.86% 0.779 87.38% 7.026 6.227 0.799 11.37% 0.837 88.63%
50%Speed 7.711 7.34 0.371 4.81% 0.598 95.19% 15.006 14.477 0.529 3.53% 0.808 96.48% 30.273 29.232 1.041 3.44% 0.885 96.56%
90%Speed 13.543 13.153 0.39 2.88% 0.593 97.12% 26.318 25.758 0.56 2.13% 0.799 97.87% 52.871 51.724 1.147 2.17% 0.886 97.83%
100%Speed 15.019 14.632 0.387 2.58% 0.624 97.43% 29.464 28.886 0.578 1.96% 0.819 98.04% 58.669 57.491 1.178 2.01% 0.89 97.99%
ote: N All 10% speed is taken at 5Hz.
Table 72. 400 V FR5-150hp efficiency rating
400 V FR5-150hp
25%Torque 50%Torque 100%To rque
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
Pin
(kW)
Pout
(kW)
Ploss
(kW)
Ploss
(%)
Power
factor
output
Efficiency
(%)
10%Speed 2.833 2.382 0.451 15.92% 0.689 84.00% 5.823 5.13 0.693 11.90% 0.817 88.10% 12.051 10.758 1.293 10.73% 0.852 89.27%
50%Speed 14.992 14.456 0.536 3.58% 0.745 96.43% 32.798 31.858 0.94 2.87% 0.899 97.13% 64.38 62.431 1.949 3.03% 0.919 96.97%
90%Speed 28.276 27.675 0.601 2.13% 0.759 97.87% 59.715 58.641 1.074 1.80% 0.902 98.20% 111.45 109.307 2.143 1.92% 0.925 98.08%
100%Speed 30.607 30.022 0.585 1.91% 0.763 98.09% 63.925 62.905 1.02 1.60% 0.904 98.41% 120.93 118.876 2.054 1.70% 0.926 98.30%
ote: N All 10% speed is taken at 5Hz.

Table of Contents

Related product manuals