Step 5—Standard Parameter List
PowerXL DH1 Series Variable Frequency Drives MN040039EN—April 2018 www.eaton.com 23
Notes
1
Parameter value can only be changed after the drive has stopped.
2
Parameter value will be set to be default when changing macros.
3
Input function is Level sensed.
4
Input function is Edge sensed.
5
Input function is Edge sensed when using StartP/StopP start logic.
P3.2.8
2
Torque Limit Supv Val -1000.0 1000.0 % 100.0 160
P3.2.9
2
Torque Limit Supv Hyst 1.0 5.0 % 1.0 2202
P3.2.10
2
Ref Limit Supv 0 161 See Par ID 154
P3.2.11
2
Ref Limit Supv Val 0.00 See Par ID 102 Hz 0.00 162
P3.2.12
2
Ref Limit Supv Hyst 0.10 1.00 Hz 0.10 2203
P3.2.13
2
Temp Limit Supv 0 165 See Par ID 154
P3.2.14
2
Temp Limit Supv Val -10.0 75.0 °C 40.0 166
P3.2.15
2
Temp Limit Supv Hyst 1.0 10.0 °C 1.0 2204
P3.2.16
2
Power Limit Supv 0 167 See Par ID 154
P3.2.17
2
Power Limit Supv Val -200.0 200.0 % 0.0 168
P3.2.18
2
Power Limit Supv Hyst 0.1 10.0 % 0.1 2205
P3.2.19
2
AI Supv Select 0 170 0 = AI1
1 = AI2
P3.2.20
2
AI Limit Supv 0 171 See Par ID 154
P3.2.21
2
AI Limit Supv Val 0.00 100.00 % 0.00 172
P3.2.22
2
AI Supv Hyst 1.00 10.00 % 1.00 2198
P3.2.23
2
Motor Current 1 Supv 0 2189 See Par ID 154
P3.2.24
2
Motor Current 1 Supv Value 0.0 DriveNomCurr
CT*2
A DriveNomCurrCT 2190
P3.2.25
2
Motor Current 1 Supv Hyst 0.1 1.0 A 0.1 2196
P3.2.26
2
Motor Current 2 Supv 0 2191 See Par ID 154
P3.2.27
2
Motor Current 2 Supv Value 0.0 DriveNomCurr
CT*2
A DriveNomCurrCT 2192
P3.2.28
2
Motor Current 2 Supv Hyst 0.1 1.0 A 0.1 2197
P3.2.29
2
Second AI Supv Select 0 2193 See Par ID 170
P3.2.30
2
Second AI Limit Supv 0 2194 See Par ID 154
P3.2.31
2
Second AI Limit Supv Val 0.00 100.00 % 0.00 2195
P3.2.32
2
Second AI Supv Hyst 1.00 10.00 % 1.00 2199
Table 23. Supervisions—P3.2, continued
Code Parameter Min. Max. Unit Default ID Note