56
Appendix A—Technical data and specifi cations
POWERXL SERIES VFD MN040002EN—February 2018 www.eaton.com
Appendix A—Technical data and speci cations
Technical data
Table 42. PowerXL Series
Attribute Description Specification
Input ratings Input voltage Uin 208 V to 240 V, 380 V to 500 V, 525 V to 600 V, –15 to 10%
Input frequency 50 Hz to 60 Hz (variation up to 45 Hz to 66 Hz)
Connection to power Once per minute or less
Starting delay 3 s (FR0 to FR2), 4 s (FR3), 5 s (FR4), 6 s (FR5 and FR6)
Short-circuit withstand rating 100 kAIC (fuses and circuit breakers)
Output ratings Output voltage 0 to Uin
Continuous output current I
L
: ambient temperature maximum 40 °C, up to 60 °C with derating, overload 1.1 x I
L
(1 min./10 min.)
I
H
: ambient temperature maximum 50 °C, up to 60 °C with derating, overload 1.5 x I
H
(1 min./10 min.)
Overload current 150% respectively 110% (1 min./10 min.)
Initial output current 200% (2 s / 20 s) based of the drives rated nameplate I
H
current rating.
Output frequency 0–400 Hz (standard)
Frequency resolution 0.01 Hz
Control characteristics Control methods Frequency control
Speed control
Open-loop speed control
Open-loop torque control
Switching frequency 230 V / 480 V Range:
FR0–3: 1 kHz to 12 kHz
FR4–6: 1 kHz to 10 kHz
230 V / 480 V defaults:
FR0–3: 4 kHz
FR4–5: 3.6 kHz
FR6: 2 kHz
600 V range:
FR1–6: 1 kHz to 6 kHz
600 V defaults:
FR1–6: 1.5 kHz
Automatic switching frequency derating in case of overload.
Frequency reference Analog input: resolution 0.1% (10-bit), accuracy +1%
Analog output: resolution 0.1% (10-bit), accuracy +1%
Panel reference: resolution 0.01 Hz
Field weakening point 20 Hz to 400 Hz
Acceleration time 0.1 s to 3000 s
Deceleration time 0.1 s to 3000 s
Braking torque DC brake: 30% x Motor Rated Torque (Tn) (without brake chopper)
Dynamic braking (with optional brake chopper using an external brake resistor):
100% continuous maximum rating
Ambient conditions Ambient operating temperature –10 °C (no frost) to +50 °C, up to +60 °C with derating (CT)
–10 °C (no frost) to +40 °C, up to +60 °C with derating (VT)
Storage temperature –40 °C to +70 °C
Relative humidity 0–95% RH, noncondensing, non-corrosive
Air quality:
• Chemical vapors
• Mechanical particles
Tested according to IEC 60068-2-60 Test Key:
Flowing mixed gas corrosion test, Method 1 (H2S [hydrogen sulfide] and SO2 [sulfur dioxide])
Designed according to:
IEC 60721-3-3, unit in operation, class 3C2
IEC 60721-3-3, unit in operation, class 3S2