Appendix A—Parameter ID list
POWERXL SERIES VFD MN040010EN—June 2018 www.eaton.com
Menu
Item
No.
Modbus
Register
PROFIBUS EtherNet/IP DeviceNet
Parameter
Description
Data
Type
Length
(in Bytes)
Display
FormatPNU
PNU
SubIndex Class Instance Attribute Class Instance Attribute
P9.562427NANA NANANANANANASTO Fault ResponseBYTE1 x0
P9.572483NANA NANANANANANAFault Reset StartBYTE1 x0
P10.1 1294 2100 0 160 1 216 170 1 1 PID1 Control Gain INTEGER 2 x100
P10.2129521010 160121717012PID1 Control ITimeINTEGER2x100
P10.3129621020 160121817013PID1 Control DTimeINTEGER2x100
P10.4129728700 160121917014PID1 Process UnitBYTE1x0
P10.5 1298 2871 0 160 1 221 170 1 5 PID1 Process Unit
Min
DOUBLE 4 x100
P10.6 1300 2872 0 160 1 222 170 1 6 PID1 Process Unit
Max
DOUBLE 4 x100
P10.7 1302 2873 0 160 1 220 170 1 7 PID1 Process Unit
Decimal
BYTE 1 x0
P10.8130328500 160122317018PID1 Error InversionBOOLEAN1x0
P10.9130428510 160122417019PID1 Dead BandDOUBLE4x100
P10.10 1306 2852 0 160 1 225 170 1 10 PID1 Dead Band
Delay
INTEGER 2 x100
P10.11 1307 2170 0 160 1 226 170 1 11 PID1 Keypad Set
Point 1
DOUBLE 4 x100
P10.12 1309 2179 0 160 1 227 170 1 12 PID1 Keypad Set
Point 2
DOUBLE 4 x100
P10.13 1311 2151 0 160 1 228 170 1 13 PID1 Ramp Time INTEGER 2 x100
P10.14 1312 2110 0 160 1 229 170 1 14 PID1 Set Point 1
Source
BYTE 1 x0
P10.15 1313 2168 0 160 1 230 170 1 15 PID1 Set Point 1 Min INTEGER 2 x100
P10.16 1314 2169 0 160 1 231 170 1 16 PID1 Set Point 1 Max INTEGER 2 x100
P10.17 1315 2136 0 160 1 232 170 1 17 PID1 Set Point 1
Sleep Enable
BOOLEAN 1 x0
P10.18 2396 NA NA NA NA NA NA NA NA PID1 Set Point 1
Sleep Unit Sel
BYTE 1 x0
P10.19 2450 2137 0 NA NA NA 170 1 18 PID1 Set Point 1
Sleep Level
DOUBLE 4 x100
P10.20 1317 2138 0 160 1 234 170 1 19 PID1 Set Point 1
Sleep Delay
INTEGER 2 x0
P10.21 1318 2139 0 160 1 235 170 1 20 PID1 Set Point 1
Wake Up Level
DOUBLE 4 x100
P10.22 1320 2154 0 160 1 236 170 1 21 PID1 Set Point 1
Boost
BYTE 1 x10
P10.23 1321 2116 0 160 1 237 170 1 22 PID1 Set Point 2
Source
BYTE 1 x0
P10.24 1322 2177 0 160 1 238 170 1 23 PID1 Set Point 2 Min INTEGER 2 x100
P10.25 1323 2178 0 160 1 239 170 1 24 PID1 Set Point 2 Max INTEGER 2 x100
P10.26 1324 2140 0 160 1 240 170 1 25 PID1 Set Point 2
Sleep Enable
BOOLEAN 1 x0
P10.27 2397 NA NA NA NA NA NA NA NA PID1 Set Point 2
Sleep Unit Sel
BYTE 1 x0
P10.28 2452 2141 0 NA NA NA 170 1 26 PID1 Set Point 2
Sleep Level
DOUBLE 4 x100
P10.29 1326 2142 0 160 1 242 170 1 27 PID1 Set Point 2
Sleep Delay
INTEGER 2 x0
P10.30 1327 2143 0 160 1 243 170 1 28 PID1 Set Point 2
Wake Up Level
DOUBLE 4 x100
P10.31 1329 2157 0 160 1 244 170 1 29 PID1 Set Point 2
Boost
BYTE 1 x10
P10.32 1330 2171 0 160 1 245 170 1 30 PID1 Feedback
Function
BYTE 1 x0
P10.33 1331 2153 0 160 1 246 170 1 31 PID1 Feedback Gain INTEGER 2 x10
Table 205. DG1 Parameter ID list, continued