219
Appendix A—Parameter ID list
POWERXL SERIES VFD MN040010EN—June 2018 www.eaton.com
Menu Item
No.
Modbus
Register
PROFIBUS
Parameter Description
Data
Type
Length
(in Bytes)
Display
FormatPNU
PNU
SubIndex
B9.1.3 2136 NA NA Protocol Status BYTE 1 x0
B9.2.1 2137 NA NA MAC ID BYTE 1 x0
B9.2.2 2138 NA NA Baud Rate BYTE 1 x0
B9.2.3 2187 NA NA IO Poll Type BYTE 1 x0
B9.2.4 2212 NA NA Dnet Comm Timeout INTEGER 2 x0
B9.2.5 2519 NA NA Comm Card FB Fault Response BYTE 1 x0
B11.1.1 910 710 2 Board Status BYTE 1 x0
B11.1.2 1067 NA NA Firmware Version INTEGER 4 x0
B11.1.3 915 550 200 DI1, DI2, DI3 BYTE 1 x0
B11.1.4 914 761 2 DO1, DO2, DO3 BYTE 1 x0
B11.1.5 917 593 200 Thermistor Resistor DOUBLE 4 x0
B11.1.6 913 753 200 Thermistor State BYTE 1 x0
B11.2.1 244 461 200 DO1 Function BYTE 1 x0
B11.2.2 245 461 201 DO2 Function BYTE 1 x0
B11.2.3 246 461 202 DO3 Function BYTE 1 x0
B11.2.4 916 343 200 Thermistor Config BYTE 1 x0
B12.1.1 910 710 2 Board Status BYTE 1 x0
B12.1.2 1067 NA NA Firmware Version INTEGER 4 x0
B12.1.3 920 560 200 AI1 Value INTEGER 2 x1000
B12.1.4 923 570 200 AO1 Value INTEGER 2 x1000
B12.1.5 925 570 201 AO2 Value INTEGER 2 x1000
B12.2.1 919 NA NA AI1 Mode BYTE 1 x0
B12.2.2 129 260 200 AI1 Signal Range BYTE 1 x0
B12.2.3 130 264 200 AI1 Custom Min INTEGER 2 x100
B12.2.4 131 265 200 AI1 Custom Max INTEGER 2 x100
B12.2.5 128 266 200 AI1 Filter Time INTEGER 2 x100
B12.2.6 132 267 200 AI1 Signal Invert BOOLEAN 1 x0
B12.2.7 922 276 200 AO1 Mode BYTE 1 x0
B12.2.8 275 460 200 AO1 Function BYTE 1 x0
B12.2.9 276 279 200 AO1 Minimum BYTE 1 x0
B12.2.10 277 277 200 AO1 Filter Time INTEGER 2 x100
B12.2.11 278 274 200 AO1 Scale INTEGER 2 x0
B12.2.12 279 278 200 AO1 Inversion BOOLEAN 1 x0
B12.2.13 280 275 200 AO1 Offset INTEGER 2 x100
B12.2.14 924 276 201 AO2 Mode BYTE 1 x0
B12.2.15 281 460 201 AO2 Function BYTE 1 x0
B12.2.16 282 279 201 AO2 Minimum BYTE 1 x0
B12.2.17 283 277 201 AO2 Filter Time INTEGER 2 x100
B12.2.18 284 274 201 AO2 Scale INTEGER 2 x0
B12.2.19 285 278 201 AO2 Inversion BOOLEAN 1 x0
B12.2.20 286 275 201 AO2 Offset INTEGER 2 x100
B13.1.1 910 710 2 Board Status BYTE 1 x0
B13.1.2 1067 NA NA Firmware Version INTEGER 4 x0
B13.1.3 926 762 2 RO1, RO2, RO3 BYTE 1 x0
B13.2.1 552 451 200 RO1 Function BYTE 1 x0
B13.2.2 555 451 201 RO2 Function BYTE 1 x0
B13.2.3 556 451 202 RO3 Function BYTE 1 x0
B14.1.1 910 710 2 Board Status BYTE 1 x0
B14.1.2 1067 NA NA Firmware Version INTEGER 4 x0
B14.1.3 931 757 2 PT100 State INTEGER 6 x0
B14.1.4 928 NA NA PT100 Values INTEGER 6 x10
Table 206. DH1 Parameter ID list, continued