4 Accessories
4.7 Device-specific accessories for devices with an IP20 degree of protection
100 DC1-S…20…, DC1-S…OE1 Variable Frequency Drives 05/21 MN040058EN www.eaton.com
4.7.2 DXC-EXT-2RO output expansion
Figure 68: DXC-EXT-2RO
Expansion module DXC-EXT-2RO can be used to convert digital output DO1
(control signal terminals 8 and 9) on DC1-S… variable frequency drives to a
dry relay output K2 (N/O). When this option is used, the variable frequency
drive will have two dry relay outputs available and will be able to switch
voltages of up to 250 V AC and 220 V DC.
Table 23: DXC-EXT-2RO connection terminals
Connection
terminal
Signal Description Default Setting
1+24V Control voltage for the
digital inputs
100 mA max.
Reference potential: 0 V
(terminal 7)
–
2DI1 Digital Input 1 8 - 30 V = HIGH, R
i
> 6 kΩ FWD
3DI2 Digital input 2 8 - 30 V = HIGH, R
i
> 6 kΩ Select Quick-Dec
4 AI2/DI3 Analog input 2 or digital
input 3
analog:
0 - 10 V, R
i
> 72 kΩ
0/4 - 20 mA, R
B
= 500 Ω
digital:
8 - 30 V = HIGH, R
i
> 72 kΩ
Select AI1REF/f-Fix1
5+10 V
Reference voltage 10 mA max.
Reference potential: 0 V
(terminal 7)
–
6 AI1/DI4 Analog input 1 or digital
input 4
analog:
0 - 10 V, R
i
> 72 kΩ
0/4 - 20 mA, R
B
= 500 Ω
digital:
8 - 30 V = HIGH, R
i
> 72 kΩ
AI1 REF
(analog, 0 - 10 V)
70V Common reference potential for all digital and analog inputs
and outputs
–
8K23
Relay RO2
(normally open)
250 V, 1 A AC/220 V, 1 A DC Output Frequency
(analog, 0 - 10 V)
9K24
Relay RO2
(normally open)
250 V, 1 A AC/220 V, 1 A DC –
10 K13
Relay RO1
(normally open)
250 V, 6 A AC/30 V, 5 A DC
RUN, enable signal for
device activated
11 K14