EasyManua.ls Logo

Eaton PowerXL - DXC-EXT-2 RO Output Expansion

Eaton PowerXL
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Accessories
4.7 Device-specific accessories for devices with an IP20 degree of protection
100 DC1-S…20…, DC1-S…OE1 Variable Frequency Drives 05/21 MN040058EN www.eaton.com
4.7.2 DXC-EXT-2RO output expansion
Figure 68: DXC-EXT-2RO
Expansion module DXC-EXT-2RO can be used to convert digital output DO1
(control signal terminals 8 and 9) on DC1-S… variable frequency drives to a
dry relay output K2 (N/O). When this option is used, the variable frequency
drive will have two dry relay outputs available and will be able to switch
voltages of up to 250 V AC and 220 V DC.
Table 23: DXC-EXT-2RO connection terminals
Connection
terminal
Signal Description Default Setting
1+24V Control voltage for the
digital inputs
100 mA max.
Reference potential: 0 V
(terminal 7)
2DI1 Digital Input 1 8 - 30 V = HIGH, R
i
> 6 kΩ FWD
3DI2 Digital input 2 8 - 30 V = HIGH, R
i
> 6 kΩ Select Quick-Dec
4 AI2/DI3 Analog input 2 or digital
input 3
analog:
0 - 10 V, R
i
> 72 kΩ
0/4 - 20 mA, R
B
= 500 Ω
digital:
8 - 30 V = HIGH, R
i
> 72 kΩ
Select AI1REF/f-Fix1
5+10 V
Reference voltage 10 mA max.
Reference potential: 0 V
(terminal 7)
6 AI1/DI4 Analog input 1 or digital
input 4
analog:
0 - 10 V, R
i
> 72 kΩ
0/4 - 20 mA, R
B
= 500 Ω
digital:
8 - 30 V = HIGH, R
i
> 72 kΩ
AI1 REF
(analog, 0 - 10 V)
70V Common reference potential for all digital and analog inputs
and outputs
8K23
Relay RO2
(normally open)
250 V, 1 A AC/220 V, 1 A DC Output Frequency
(analog, 0 - 10 V)
9K24
Relay RO2
(normally open)
250 V, 1 A AC/220 V, 1 A DC
10 K13
Relay RO1
(normally open)
250 V, 6 A AC/30 V, 5 A DC
RUN, enable signal for
device activated
11 K14
1 2 3 4 5 6 7 8 9 10 11

Table of Contents

Related product manuals