B-2       
(PTO ENGAGE)
B-16          
(PTO CONFIRM)
VBATT 
(Fused)
B-15 (PTO REQUEST)
PTO 
Engage 
Relay
PTO Lamp/LED
B-14  (RTN_2)
CHASSIS GROUND
B-5 (RTN_1)
30
87
A
87
86
85
PTO 01P
1
PTO 
VBATT
SW02
SW04
SW03
SW01
DPST
PTO w/Confirm Switched to Chassis GND
Inside or on Dashboard
L+
L-
PTO-Power
PTO-Confirm
PTO-Ground
Contact Customer Support 
Engineering for additional options
Switches shown in inactive posistion
PTO with Confirm Switched to Chassis
From To Description Notes
TCM - B-14 DPST - SW01 PTO Request
DPST - SW02 TCM - B-15 PTO Request
Vbatt
DPST - SW03 PTO Power Vbatt should be fused to protect 
wiring to
 PTO and PTO.
DPST - SW04 PTO Engage Relay - 30 PTO Engage
TCM - B-5 PTO Engage Relay - 86 PTO Engage
PTO Engage Relay - 85 TCM - B-2 PTO Engage
PTO Engage Relay - 87 PTO - PTO-Power PTO Engage
PTO - PTO-Ground Chassis GND PTO Ground
PTO - PTO-Confirm.
B-16
PTO Confirm Splice
PTO Lamp - L(-)
Vbatt
PTO Lamp - L(+) PTO Confirm Vbatt should be fused to protect 
Lam
p circuit.
40
PTO Interface
PTO Interface