Figure 9-6: Analog Output Invert
2.3.7 Analog output invert ID309
Inverts the analog output signal:
Maximum output signal = 0%
Minimum output signal = Maximum set value (parameter 2.3.9)
0 Not inverted
1 Inverted
See parameter 2.3.9 below.
2.3.8 Analog output minimum ID310
Sets the signal minimum to either 0 mA or 4 mA (living zero). Note the difference in
the analog output scaling in parameter 2.3.9.
2.3.9 Analog output scale ID311
Scaling factor for the analog output.
Analog
Output
Current
20 mA
12 mA
10 mA
4 mA
0 mA
ID311 = 50%
ID311 = 100%
Max. Value of Signal
Selected with ID307
ID311 =
200%
0 0.5 1.0