SLX9000 Adjustable Frequency Drives User Manual
1-8 For more information visit: www.eaton.com
MN04003020E
January 2009
Table 1-8: Technical Information (Continued)
Description Specification
Ambient Conditions (Continued)
Vibration
EN 50178/EN 60068-2-6
5 – 150 Hz
Displacement amplitude 1 mm (peak) at 5 – 15.8 Hz
Max acceleration amplitude 1G at 15.8 – 150 Hz
Shock
EN 50178, IEC 68-2-27
UPS Drop Test (for applicable UPS weights)
Storage and shipping: max 15G, 11 mS (in package)
Enclosure Class NEMA Type 1/IP21 or NEMA Type 12/IP54
EMC
Immunity Complies with EN 50082-1, -2, EN 61800-3
Emissions MF4 – MF6: EMC-level H: EN 61800-3 (1996)+A11 (2000)
1. environment, restricted use; 2. environment
Safety
EN 50178, EN 60204-1, CE, UL, cUL, FI, GOST R, IEC 61800-5
(see unit nameplate for more detailed approvals)
Control Connections
Analog Input Voltage 0 – 10V, R
i
= 200 kΩ,
Resolution 10 bit, accuracy ±1%
Analog Input Current 0(4) – 20 mA, R
i
= 250Ω differential
Digital Inputs 3 positive logic; 18 – 24V DC
Auxiliary Voltage +24V, ±15%, max. 100 mA
Output Reference Voltage +10V, +3%, max. load 10 mA
Analog Output 0(4) – 20 mA; R
L
max. 500Ω; Resolution 16 bit;
Accuracy ±1%
Relay Outputs 1 programmable change-over relay output
Switching capacity: 24V DC/8A, 250V AC/8A, 125V DC/.4A
Protections
Overvoltage Protection Yes
Undervoltage Protection Yes
Ground Fault Protection In case of ground fault in motor or motor cable, only the drive is
protected
Unit Overtemperature Protection Yes
Motor Overload Protection Yes
Motor Stall Protection Yes
Motor Underload Protection Yes
Short Circuit Protection of +24V
and +10V Reference Voltages
Yes
Overcurrent Protection Trip limit 4.0*I
H
instantaneously