SLX9000 Adjustable Frequency Drives User Manual
5-8 For more information visit: www.eaton.com
MN04003020E
January 2009
Table 5-5: Monitored Signals
Parameter Menu (P2)
Parameter values can be edited by entering the Parameter Menu from the Main Menu when
the location indication P2 is visible on the display. The value editing procedure is presented
in Figure 5-6.
Pressing Menu Button Right once takes you to the Parameter Group Menu (G#). Locate the
desired parameter group by using the Browser buttons and press Menu Button Right again
to see the group and its parameters. Use the Browser buttons to find the parameter (P#) you
want to edit. Pressing Menu Button Right takes you to the edit mode. As a sign of this, the
parameter value starts to blink. You can now change the value in two different ways:
Set the desired value with the Browser buttons and confirm the change with the ENTER
button. Consequently, the blinking stops and the new value is visible in the value field.
Press Menu Button Right once more. Now you will be able to edit the value digit by
digit. This may come in handy, when a relatively greater or smaller value than that on
the display is desired. Confirm the change with the ENTER button.
Code Signal Name Unit ID Description
V1.1 Output frequency Hz 1 Frequency to the motor
V1.2 Frequency reference Hz 25
V1.3 Motor speed rpm 2 Calculated motor speed
V1.4 Motor current A 3 Measured motor current
V1.5 Motor torque % 4 Calculated actual torque/nominal torque of the motor
V1.6 Motor power % 5 Calculated actual power/nominal power of the motor
V1.7 Motor voltage V 6 Calculated motor voltage
V1.8 DC-link voltage V 7 Measured DC-link voltage
V1.9 Unit temperature °C 8 Heatsink temperature
V1.10 Analog input 1 13 AI1
V1.11 Analog input 2 14 AI2
V1.12 Analog output current mA 26 AO1
V1.13 Analog output current 1,
expander board
mA 31
V1.14 Analog output current 2,
expander board
mA 32
V1.15 DIN1, DIN2, DIN3 15 Digital input statuses
V1.16 DIE1, DIE2, DIE3 33 I/O expander board: Digital input statuses
V1.17 RO1 34 Relay output 1 status
V1.18 ROE1, ROE2, ROE3 35 I/O exp. board: Relay output statuses
V1.19 DOE1 36 I/O exp. board: Digital output 1 status
V1.20 PID Reference % 20 In percent of the maximum process reference
V1.21 PID Actual value % 21 In percent of the maximum actual value
V1.22 PID Error value % 22 In percent of the maximum error value
V1.23 PID Output % 23 In percent of the maximum output value
V1.24 Autochange outputs
1, 2, 3
30 Used only in pump and fan control