TRSM0940 Auxiliary Section Service Procedures | MHP/MXP/VHP/VXP Auxiliary Section Removal and Disassembly
6. Install Auxiliary Counter Shaft Support straps using 3
of the 4 bolts from the Auxiliary Counter Shaft Bearing
covers. Use the longer bolts to secure the center of
each strap as this will ensure the Auxiliary Counter-
shafts will remain in time.
7. Remove the 19 bolts that fasten the Auxiliary Section
to the Transmission Main Case.
8. Using a pry bar to assist, separate the Auxiliary Section
from the transmission main case enough to fit the aux-
iliary section hanger (RR1006TR) into place.
Note: It may be necessary to drive the dowel pins for-
ward to help dislodge the Auxiliary Section.