1 Description of the Modular PLCs XControl: XC-104-…, XC-204-…, XC-303-…
1.2 Communications and interfaces - decentralized expansion
12
1.2 Communications and interfaces - decentralized expansion
Modular PLCs XControl: XC-104-…, XC-204-…, XC-303-… support distributed
expansion with the use of fieldbus interfaces. The following communication
protocols are supported by the corresponding interfaces as follows:
Table 1 Overview Eaton Modular PLCs XControl: XC-104-…, XC-204-…, XC-303-…
1.3 Intended use
Modular PLCs XControl: XC-104-…, XC-204-…, XC-303-… are des
igned for
use in machine and system building applications as compact fanless PLCs
with comprehensive features and interfaces that can be used to implement
flexible state-of-the-art automation solutions.
The devices are approved for use in automation applications exclusively for
controlling machines and systems in closed spaces.
It is strictly prohibited to use the devices in order to implement safety-rele-
vant functions (in the sense of personal and machine protection).
Observe the labels on the modular PLC housing and the corresponding
approval specifications and technical data.
Any other use must be discussed and agreed upon with the manufacturer in
advance.
Modular PLCs XControl: XC-104-…, XC-204-…, XC-303-… 08/23 MN050005EN Eaton.com
→
XN300-Assist is a servicing and commissioning tool for the
XN300 system – please refer to → Section “3.12 XN300-
Assist”, page 72.
→
In order to program MFD-Titan, you will need XSOFT-CODE-
SYS-3 programming software version 3.5.9 or higher.
Designation XN300
module
s
Retai
n
Data
ETH
1GB/
100MB
RTC USB SD-
Slot
WEB-
Visu
HTML5
Interfaces
[kb}
Modbus
TCP
Server/
Client
OPC-
UA
Ether-
CAT
Master
/Slave
CAN CAN-
OPEN
RS485 Modbu
s RTU
Server/
Client
DIO
XC-303-C32-002
32 128 1x/2x ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2x MS/SL ✓ MS/SL 4x
XC-303-C21-001
32 128 -/2x ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1x MS/SL ✓ MS/SL –
XC-303-C11-000
32 128 -/1x ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1x MS/SL – – –
XC-204-C20-002
16 32 -/1x ✓ ✓ – ✓ ✓ ✓ ✓ – – –x MS/SL –
XC-204-C21-001
16 32 -/1x ✓ ✓ – ✓ ✓ ✓ ✓ 1x MS/SL ✓ – –
XC-204-C11-003
16 32 -/2x ✓ ✓ – ✓ ✓ ✓ – 1x MS/SL – MS/SL 2x
XC-204-C10-000
16 32 -/2x ✓ ✓ – ✓ ✓ – – – – ✓ – 2x
XC-104-C10-000
6 4 -/1x ✓ ✓ –
✓
✓ – – – – –x – –