13.CONFEO PREMIX P COMPONENT DEFINITIONS
Siphon
Subject
Description
Part’s Function
The component that allows the discharge of condensing water and rainwater
without allowing the discharge of waste gas.
Impact in Case of
Malfunction
1-
Water rises in the siphon due to siphon clogging.
2-
The siphon discharges waste gas to the external environment.
Main Associated Error
Codes
E01
Error Diagnostics-Test
Method and Maintenance
Visually inspect that there is no dirt, burrs, etc. in the siphon and the siphon
is clean.
Siphon cleaning steps:
1- Move the siphon upwards.
2- Turn it counterclockwise.
3-
Move downwards using a hand tool or by hand.
4-
Remove the filth accumulated in the siphon by washing.
5-
If there is filth in the condensing water hose, clean it as well.
1
2 3
4 5
Table 9