9.2- Gas and Water Connections
Water and gas supply connections between the boiler and the mounting bracket can be fixed with the
pipes and the nipples.
9.2.1- HM Model
a c  e
a) CH flow ¾ ‘’ (hot)
b) DHW outlet ½ ‘’ (hot)
c) Gas inlet ¾’’
d) DHW inlet ½ ‘’ (cold)
e) CH return ¾’’ (cold)
-A suitable valve should be mounted on the gas inlet
and CH & DHW water circuit. In addition, a water filter
must be mounted on CH (3/4”) return and DHW (1/2”)
inlet.
- A plastic pipe should be fixed the outlet tap of the
three bar relief valve and the pipe should be connected
to the drain line.
- The connection between the appliance and gas
supply must be made with a flexible pipe.
- National and local requirements must be taken into
consideration.