EasyManuals Logo

ECD DO82 Instructional Manual

ECD DO82
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
HYDRA-DS NO
3
-N Page 47
S80 Serial Number (hi word)
Unit Serial Number (32 bit integer hi word)
2
32 bit
Long
Integer
R
54
36
S80 Serial Number (lo word)
Unit Serial Number (32 bit integer lo word)
55
37
S80 Fault Status
1
16 bit
Integer
R
56
38
S80 Sensor Type
Specific S80 sensor type (see S80 Sensor Types tab)
1
16 bit
Integer
R
57
39
S80 Sensor Chemical Type
Specific chemicals the S80 is set to detect (see S80
Sensor Types tab)
1
16 bit
Integer
RW
Y
58
3A
S80 Max Range (hi word)
Max sensor range (bytes 3 and 2)
2
32 bit
Floating
Point
R
59
3B
S80 Max Range (lo word)
Max sensor range (bytes 1 and 0)
60
3C
S80 Min Range (hi word)
Min sensor range (bytes 3 and 2)
2
32 bit
Floating
Point
R
61
3D
S80 Min Range (lo word)
Min sensor range (bytes 1 and 0)
62
3E
S80 Sensor Value (hi word)
Current sensor value (bytes 3 and 2)
2
32 bit
Floating
Point
R
63
3F
S80 Sensor Value (lo word)
Current sensor value (bytes 1 and 0)
64
40
S80 Sensor Voltage (hi
word)
Corresponding sensor voltage to the sensor value
(byte 3 and byte 2)
2
32 bit
Floating
Point
R
65
41
S80 Sensor Voltage (lo
word)
Corresponding sensor voltage to the sensor value
(byte 1 and byte 0)
66
42
S80 Sensor Temperature (hi
word)
Sensor Temperature (bytes 3 and 2)
2
32 bit
Floating
Point
R
67
43
S80 Sensor Temperature (lo
word)
Sensor Temperature (bytes 1 and 0)
68
44
S80 Sensor is a Sentinel
Sensor is a Sentinel Type (0 - No, 1 - Yes)
1
16 bit
Integer
R
69
45
S80 Sentinel Life %
% of Sensor life remaining
1
16 bit
Integer
R
70
46
S80 Sentinel Vs (hi word)
Scaled Sentinel Voltage (in mV) normalized to Vo
(bytes 3 and 2)
2
32 bit
Floating
Point
R
71
47
S80 Sentinel Vs (lo word)
Scaled Sentinel Voltage (in mV) normalized to Vo
(bytes 1 and 0)
72
48
S80 Sentinel Vo (hi word)
Sentinel 100% value (in mV) on the life relative to 0V
(bytes 3 and 2)
2
32 bit
Floating
Point
RW
Y
73
49
S80 Sentinel Vo (lo word)
Sentinel 100% value (in mV) on the life relative to 0V
(bytes 1 and 0)
74
4A
S80 Sentinel Range (hi word)
Sentinel Range (bytes 3 and 2)
2
32 bit
Floating
Point
RW
Y
75
4B
S80 Sentinel Range (lo word)
Sentinel Range (bytes 1 and 0)
76
4C
Sensor Full Name (18
characters max)
ASCII character bytes 0 and 1, ex. "AB" A - 65 (41
hexidecimal), B - 66 (42 hex), send 6566 (4142 hex).
The characters permitted are space ' ' (32 base 10, 20
hex) through '}' 125 base 10, 7D hex).
1
16 bit
Integer
RW
Y
77
4D
Sensor Full Name
ASCII bytes 2 and 3
1
16 bit
Integer
RW
Y
78
4E
Sensor Full Name
ASCII bytes 4 and 5
1
16 bit
Integer
RW
Y
79
4F
Sensor Full Name
ASCII bytes 6 and 7
1
16 bit
Integer
RW
Y
80
50
Sensor Full Name
ASCII bytes 8 and 9
1
16 bit
Integer
RW
Y
81
51
Sensor Full Name
ASCII bytes 10 and 11
1
16 bit
Integer
RW
Y
82
52
Sensor Full Name
ASCII bytes 12 and 13
1
16 bit
Integer
RW
Y
83
53
Sensor Full Name
ASCII bytes 14 and 15
1
16 bit
Integer
RW
Y
84
54
Sensor Full Name
ASCII bytes 16 and 17
1
16 bit
Integer
RW
Y
85
Sensor Abbreviated Name (8
characters max)
ASCII character bytes 0 and 1, ex. "AB" A - 65 (41
hexidecimal), B - 66 (42 hex), send 6566 (4142 hex).
The characters permitted are space ' ' (32 base 10, 20
hex) through '}' 125 base 10, 7D hex).
1
16 bit
Integer
RW
Y
86
56
Sensor Abbreviated Name
ASCII bytes 2 and 3
1
16 bit
Integer
RW
Y
87
57

Table of Contents

Other manuals for ECD DO82

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ECD DO82 and is the answer not in the manual?

ECD DO82 Specifications

General IconGeneral
BrandECD
ModelDO82
CategoryTransmitter
LanguageEnglish

Related product manuals