417101774_EMP_KKS_E60_E.doc - 20 - Rev. 8-03.10
7.2.4 Connector assignments of slot III (4-terminal) output for alarm and stroke signal
Fig. 7.17
2
1
4
3
1: Low-level advance warning, empty report and fault
2: Low-level advance warning, empty report and fault
3: Stroke signal (+)
4: Stroke signal (-)
(plug assignments: see also chapter 14.5.3 “Technical Specifications“)
# Remove the protective cap
# Mount the connector plug according to the connector assignment.
WARNING
Only use a connector plug from our product range! (included in the delivery scope)
7.2.4.1 Installing the alarm or fault report output at 24 V
Fig. 7.18
Standard configuration:
closed = empty report container active or error message
Other configuration see chapter 7.2.4.4 (Hardware) and chapter 10.3.9 (software /menu)