14 Technical Specifications
14.1 Pump key
1. Electrical version
...
E 60 =
(for explanation, see chapter 14.1.1)
...
2. Pump output 50 Hz (60 Hz)
00002 = 0,2 l/h (0,24 l/h)
00005 = 0,5 l/h (0,6 l/h)
00009 = 0,9 l/h (1,1 l/h)
00014 = 1,4 l/h (1,7 l/h)
3. Pump head material
PV = PVDF (standard)
4. Metering backpressure (not freely selectable)
10 = 10 bar s (8 bar)
5. Gasket material
FP = Viton B (standard)
EP = EPDM
KA = Kalrez
6. Ball material
KE = Ceramic (Standard)
GL = Glas
7. Valve material
PV = PVDF (standard)
8. Valve spring
99 = without spring (standard)
9. Mains power supply
01 = mains power cable 2 m (standard)
02 = 3-core mains power cable 2.4m cable end sleeves
09 = mains power cable, US version
10 = appliance plug
13 = mains power cable, Italian version
10. Voltage/frequency
01 = 115V / 50 Hz
02 = 115V / 60 Hz
03 = 230V / 50 Hz (Standard)
04 = 230V / 60 Hz
Other specifications provided on request!