4 05.10.2015 BA-21907-006-EN
EN
1. INSTALLATION
1.1. LOCATION
Low temperatures during transport/stocking may lead to dam-
age of water containing components.
Before installing the machine it should be exposed to normal
room temperature (min. 15°C) for 24h.
Rear wall clearance not required.
Level machine by turning the feet.
Distribute machine weight equally onto all feet
1.2. ELECTRICAL CONNECTION
Must be carried out by an authorized technician according to
the local and national codes.
For Australia: in accordance with AS/NZS3500.1
The electrical supply shall comply with the name-plate data.
Line fuses and cable cross section shall comply with the require-
ments.
NOTE: A cut-off device shall be provided to connect the supply cord
(isolating switch or accessible plug device).According to EN
60 335 the appliance must be connected to an equipotential
conductor. The connecting screw ( ) is located beside the
cable inlet.