EcoSmart ES50LVP Specifications

General IconGeneral
ModelES50LVP
TypeAir Handler
BrandEcoSmart
Phase1
Maximum External Static Pressure0.8 in. W.C.
Cabinet ConstructionGalvanized Steel
Voltage208/230V
Heating Capacity50, 000 BTU/h
Cooling Capacity50000 BTU
Filter TypeStandard

Summary

SAFETY INFORMATION

Safety Alerts and Signal Words

Explains safety symbols, DANGER, WARNING, and CAUTION terms.

General Safety Warnings

Covers installation, electrical, and hot water hazard warnings.

INTRODUCTION

Product Overview

Describes the ecosmart hydronic furnace, its purpose, and capabilities.

MODES OF OPERATION

Full Modulation

Details operation in full modulation mode, typically with an outdoor sensor.

Step Modulation

Explains step modulation mode, often used without an outdoor sensor.

Basic Mode

Describes basic mode, simulating standard furnace operation.

PERFORMANCE RATINGS

ES50LVP Performance Data

Presents performance data, including BTUH capacities, for the ES50LVP model.

ES90LVP Performance Data

Presents performance data, including BTUH capacities, for the ES90LVP model.

SPECIFICATIONS

Physical Data and Dimensions

Provides physical dimensions, supply air opening, and side return air data.

Blower Performance Tables

Lists ECM blower performance (CFM/amps) for ES50LVP and ES90LVP models.

QUICK START-UP PROCEDURES

Start-Up Steps

Outlines the sequential steps for safely starting up the ecosmart system.

INSTALLATION

Clearances and Freeze Protection

Specifies required clearances and advises on freeze protection.

Mounting, Piping, and Plumbing

Covers unit mounting, rear piping, and plumbing connections.

Check Valve, Pump, and System Setup

Discusses check valves, pumps, and connecting to water heaters/boilers.

PIPING DIAGRAMS

Tankless Water Heater Piping Diagram

Illustrates piping for a system using a tankless water heater.

Combi-Boiler Piping Diagram

Illustrates piping for a system using a combi-boiler.

ELECTRICAL

Electrical Information and Connections

Covers operating voltage, grounding, and making connections to quick connects.

Thermostat Wiring

Provides wiring instructions and diagrams for thermostat connections.

Ecosmart Wiring Diagram

Presents the overall wiring diagram for the ecosmart unit.

Miscellaneous Wiring

Details connections for flow switches, boiler initiate, and accessories.

DIP SWITCH OPTIONS

Switch Locations and Outdoor Temp Select

Identifies dip switch locations and how to set outdoor temperature.

Heat CFM Settings

Explains how to set heat CFM for ES90LVP and ES50LVP models.

Cool CFM and System Settings

Covers setting cool CFM and system parameters for both models.

SEQUENCE OF OPERATION

Heating Modes Operation

Details operation in Full, Step, and Basic Modulation heating modes.

Cooling, Dehumidification, and Fan Modes

Explains cooling, dehumidification, fan modes, and freeze protection.

Pump Exerciser

Explains the function and purpose of the pump exerciser.

SERVICE AND MAINTENANCE

Routine Maintenance

Provides guidance on maintaining the filter, coils, fan, and motor.

Assembly Removal

Lists the steps for safely removing the control and blower assembly.

TROUBLESHOOTING

System Start-Up and Pump Issues

Addresses thermostat call errors and external pump issues.

Heating and Water Flow Issues

Troubleshoots insufficient heat, cold water, and fan operation.

WARRANTY INFORMATION

Warranty Details

Provides details regarding the product's warranty period and where to find more information.