The flow rate can be adjusted if desired by shift-
ing the output regulator within the min. and
max. range. The device is put into operation by
the power plug.
Unplug the power plug. Pull the pump housing off
the motor body to the front with strong pressure.
Take pump wheel out of its mounting.
Wash out all pump parts thoroughly and clean
with the brush set (no. 4009560).
Possible lime deposits can be removed by putting
the pump parts in vinegar for a few hours.
Then re-assemble all the parts in the appropriate
order.
B Installation
Insert the two suckers into the bottom 2 openings
of the pump housing. Attach the pump below the
water surface to the inner wall of the tank.
C Putting into operation
D Care and maintenance
+
A Function
Motor body
Pump wheel
Pump housing
with protector
Output regulator
2 suckers
The immersion pump can only be used in the a-
quarium under water and must not run dry. Cable
length 1.5 m, temperature range max. 35°C. The
motor is protected against overheating.