EHEIM 2227 - Troubleshooting: Pump Head and Wet;Dry Leaks; Securing Pump Head Clips and Sealing Surfaces

EHEIM 2227
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
What to do when …
29
Problem RemedyCause
Filter leaks at pump head
of filter
Filter leaks at wet/dry
control
Properly close all EZ clips.
Clean sealing surfaces.
Clean sealing surfaces.
Properly install o-rings.
Not all EZ clips are closed.
Sealing surfaces or sealing
gasket is soiled.
Sealing surfaces of o-rings
soiled.
O-rings not installed or
improperly installed.
O-rings of wet/dry floater
compartment missing,
damaged or soiled.
Locking pin not closed.
Clean or replace o-rings.
Close locking pin with
locking key so that the slots
are in a horizontal position.