5
Control Panel Operating Instructions
DRY mode
AUTO LOW HIGH
MODE
Press the DRY button through the sequence below:
DESCRIPTION
AUTO
LOW
HIGH
The dehumidifier operates to achieve room conditions between
55 & 60% Relative Humidity
The fan speed & heater power are adjusted automatically
The dehumidifier operates in LOW fan speed & low heater power
The dehumidifier operates to achieve room conditions between
40 & 45% Relative Humidity
Fan speed is always high & the heater power is adjusted
automatically
MODES
Heater
Under 35
o
C Over 40
o
C
Over 60
o
C High Low Low OFF
OFF OFF OFF
Low Low OFF
OFF OFF OFF
High Low OFF
OFF OFF OFF
High
High
Low
Low
Low
Under 55
o
C
Over 60
o
C
Under 55
o
C
Over 50
o
C
Under 45
o
C
35~40
o
C
Room Temperature
Fan Speed
Room
Humidity
(%RH)
AUTO
LOW
DRY
HIGH