25
Power Up
Blue LED Red LEDGreen LEDSound
Alarm
Head Removal
Mode
Standby
Normal Operation
= LED on solid
= LED flashing
Button Test
x 1
x 1
x 1
x 1 x 1 x 1
followed
by flash every 10 Sec
followed
by flash 1 minute later
House Code
enter
Press and release
on solid blue
Press and release
on solid blue
Button Action Blue LED Red LEDGreen LED
Mode
RF Mode
In house code
House code
exit
Press and release
on flashing blue
Factory reset
Press and release on
multi-colour flashing
Remote learn
entry
In monitoring
(paired)
Press and release on
solid green
Press and release on
solid green
Enable
Monitoring
In monitoring
(failed)
Monitoring
mode exit
Press and release on
solid red
Disable
Monitoring
What you see / hear
Red LED Sound What it means What to do
Fault Conditions
rapidly after
button release
Rapid Beeping Incompatible house code Factory reset the module
and re-try
Communication failure
between module and
Alarm head
Remove the module,