12. Faults
Motor fails to start up
Causes Remedies
No mains voltage Check voltage
Pump rotor blocked -thermostat switched off Dismantle and clean pump
No intake
Causes Remedies
Intake valve not in water Immerse intake valve in water
Pump chamber without water connection Fill water into intake
Air in intake line air-tight Make sure intake line is
Intake valve leaks Clean intake valve
Strainer (intake valve) blocked Clean strainer
Max. suction height exceeded Check suction height
Inadequate delivery rate
Causes Remedies
Suction height too high Check suction height
Strainer dirty Clean strainer
Water level falling rapidly Immerse intake valve deeper
Pump performance diminishedby contaminants part Clean pump and replace wearing
Thermostat switches pump off
Causes Remedies
Motor overloaded - friction Dismantle and clean pump.
caused by foreign Prevent intake of foreign
substances too high substances (filter)
Warning!
The pump must never be allowed to run dry!
13. Orders for replacement parts
Please quote the following data when ordering replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to www.isc-gmbh.info
We draw express attention to the fact that we are not liable under the Product Liability Law for any damage
caused by our appliances if said damage results from improper repair or if parts are replaced by non-original
Einhell parts or parts not issued with our approval and the repair was not carried out by ISC Customer Service.
Anleitung GP Jet 1300 NIRO SPK7 15.02.2006 9:11 Uhr Seite 9

Related product manuals