Problem Probable cause Remedy
Motor fails to start Motor circuit breaker has been
triggered
Allow the motor to cool down and
press in the motor circuit breaker
switch
Trunk fails to split Trunk is incorrectly positioned
Trunk exceeds permitted
dimensions
Wedge fails to cut
Oil leak
Pressure setting screw has been
displaced
Position the trunk correctly
Reduce the size of the trunk
Sharpen the wedge. Remove
burrs and nicks from the wedge
Contact an authorized dealer
Contact an authorized dealer
The trunk pusher moves forward
with jolts or heavy vibrations
Air in the oil circuit Check the oil level.
Top up if necessary.
If the problem remains, contact
an authorized dealer.
Escaping oil from the cylinder or
other point.
Ventilation screw not unscrewed
during operation.
Ventilation screw not screwed tight
during transportation
Oil drainage screw not screwed
tight
Oil seal is worn
Unscrew the ventilation screw
Always tighten the ventilation
screw before transporting
Tighten the oil drainage screw
Contact an authorized dealer