Description
Set point
Different (Hysteresis)
Minimum set point
Maximum set point
Offset
Output delay start up
Anti-short cycle delay
Continious cycle delay
Compressor ON time with probe failure
Compressor OFF time with probe failure
Type of action (cooling, heating)
Temperature measurement unit
Interval between defrost cycles
Maximum lenght for defrost
Displaying during defrost
Max. display delay after defrost
Temp. alarms configuration
Maximum temp. alarm
Minimum temp. alarm
Temp. alarm delay
Delay of temp. alarm start up
Probe selection
N/A
N/A
Label
Set
Hy
LS
US
Ot
Ods
AC
CCt
COn
COF
CH
CF
ldF
Mdf
dFd
dAd
Alc
ALU
ALL
Ald
dAo
PbC
Rel
Ptb
Dixell XR30C 115 volt
Setting Celcius
-45
3
-50
0
0
1
3
0
60
5
CL
C
120
0
Set
1
Ab
-36
-50
120
24
Ptc
3
84
Setting Farenheit
-45
3
-58
0
0
1
3
0
60
5
CL
F
120
0
Set
0
Ab
-33
-58
120
24
Ptc
3
84
230 volt