- 25 -
Spares Operation 08.01 A. B. 599 51 19 69 EN
6. Technical equipment / general information
6.1 Fan after-running / appliance cooling
When the appliance has switched off, the housing fan continues operating, until the temperature has
sunk below 200° C. In case of less than 200° C, the housing fan is running approx. 10 minutes. The
remaining heat is indicated until the temperature has fallen to 40° C.
6.2 Setting time 4 seconds
After switching on and after all settings, the next setting step has to start within 4 seconds. The signal
sound confirms the expiry of 4 seconds. By pressing the corresponding key you can produce the
readiness for setting right away.
6.3 Safety switch-off of the oven
When setting function and temperature without a time limit, the safety switch-off switches off the oven
automatically, depending on the set temperature.
- with temperature setting to 120° C after 12 hours
- with temperature setting to 230° C after 6 hours.