Problem Possible cause Solution
Water flows on the
ground.
The melting water outlet does
not flow in the evaporative tray
above the compressor.
Attach the melting water outlet to
the evaporative tray.
The temperature in the
appliance is too low.
The temperature regulator is not
set correctly.
Set a higher temperature.
The temperature in the
appliance is too high.
The temperature regulator is not
set correctly.
Set a lower temperature.
The door is not closed correctly. Refer to "Closing the door".
The product temperature is too
high.
Let the product temperature de-
crease to room temperature be-
fore storage.
Many products are stored at the
same time.
Store less products at the same
time.
The temperature in the
refrigerator is too high.
There is no cold air circulation in
the appliance.
Make sure that there is cold air
circulation in the appliance.
The temperature in the
freezer is too high.
Products are too near to each
other.
Store products so that there is
cold air circulation.
Replacing the bulb
If you want to replace the bulb, do these
steps:
1. Break the circuit of the appliance.
2. Press on the rear hook and at the same
time slide the cover in the direction of
the arrow.
3. Replace the bulb with one of the same
power and specifically designed for
household appliances. the maximum
power is shown on the light bulb cover)
4. Replace the light cover by sliding it into
its original position.
5. Reconnect the appliance.
6. Open the door and check if the light
comes on.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to
"Installation".
3. If necessary, replace the defective door
gaskets. Contact the Service Center.
electrolux 13