Occurrence Solution
Dehumidier does not operate Wall plug disconnected. Push plug rmly
into wall outlet.
House fuse blown or circuit breaker
tripped. Replace fuse with time delay type
or reset circuit breaker.
The dryness level you selected has been
reached. Dehumidier automatically shuts
off when selected amount of moisture has
been removed from the air. If you want
to remove more moisture, select CON-
TINUOUS by using the humidity button or
knob. After the dehumidier starts, reset
the control to the desired setting.
Bucket not installed properly. See
“Removing Collected Water”.
Water in the bucket has reached its preset
level. Dehumidier automatically turns
off when this occurs. Empty bucket and
return bucket to position.
Dehumidier is not turned on. Turn unit on.
BUCKET FULL light is on. Remove buck-
et, empty water and re-install correctly.
Dehumidier runs too much Windows or doors near dehumidier are
open to outdoors. Close all windows or
doors to outside.
Area to be dehumidied is too large.
Check with your dealer to see if capacity
is adequate.
Air movement through dehumidier is
blocked. Grill may be dirty. Use brush at-
tachment of vacuum cleaner to clean grill.
See “Care and Cleaning“. Dehumidier
must be placed in a space that does not
restrict air owing into the rear coil or out
of the front grill.
Dehumidier has been installed or re-
started recently. The higher the moisture
in the room, the longer the dehumidier
will operate.
Dehumidier is in the CONTINUOUS
mode and will remain on in this mode, use
the humidity button or knob to set a RH%
higher level.