47
Procedure for use
Set tare to a certain value
Press b three times to
highlight ”SET TARE TO A
CERTAIN VALUE”
Press SELECT.
4785
This screen shows that
the parameter has been
entered successfully.
Press SELECT.
Set tare to a certain value
This function lets you enter a value for the tare para-
meter, i.e. a weight value which the weighing equip-
ment will disregard when showing a net weight on
the display. The function will automatically clear any
earlier tare value when you enter a new one.
If your value is not entered successfully at this point,
you will see an error message equivalent to: “FAILED.
PRESS SELECT” on the display. For troubleshooting,
see the section “Fault-finding, weighing equipment”
in the machine manual.
Press SELECT.
Use the numeric keys
to enter the tare you re-
quire, unit: hectograms; 1
hectogram = 100 grams).
For machines with weighing equipment installed only!
4780
SERVICEPROGRAM
MAKE A CHOICE:
RESET SCALE TO ZERO
RESET TARE TO ZERO
TARE SCALE
SETTARETOACERTAINVALUE
READTAREVALUE
CALIBRATE THE SCALE
SELECT
RESET SCALE TO ZERO
RESET TARE TO ZERO
TARE SCALE
SET TARE TO A CERTAIN VALUE
READTAREVALUE
CALIBRATE THE SCALE
ZERO CALIBRATION
READVERSIONNUMBER
EXIT
SELECT
SCALE ADJUSTMENTS
SETTARETOACERTAINVALUE
ENTER TARE IN HG AND
PRESS SELECT
SELECT
SELECT
SCALE ADJUSTMENTS
TARE SCALE
DONE! PRESS SELECT
SELECT
SELECT
3588