EasyManua.ls Logo

Elesta RTU300B User Manual

Elesta RTU300B
22 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
*2701619_Rev.2*
Appareil conforme aux exigences des directives
R&TTE 1999/5/CE
En raison de l'évolution des normes et du matériel, les caractéristiques indiquées par le texte
et les images de ce document ne nous engagent qu'après confirmation par nos services.
Thermostat programmable radio
pour chauffage et climatisation
Radio-controlled programmable thermostat
for heating and air-conditioning
Device complying with the requirements of directives
R&TTE 1999/5/CE
Because of changes in standards and equipment, the characteristics given in the text and
the illustrations of this document are not binding unless confirmed by our services.
Question and Answer IconNeed help?

Do you have a question about the Elesta RTU300B and is the answer not in the manual?

Elesta RTU300B Specifications

Power IconPower
battery typeLR03 or AAA-type 1.5 V
battery autonomygreater than 2 years
insulation classClass III
Transmission IconTransmission
transmission frequency868 MHz
radio range100 to 300 metres
transmission classclass I (standard EN 300 220)
Operating Environment IconOperating Environment
storage temperature-10°C to +70°C
operating temperature0°C to +40°C
protection indexIP 30
Weight and Dimensions IconWeight and Dimensions
dimensions135 x 81 x 0.87 in

Summary

Mountings

Starting up

Configuration Options

CF01 - Correction of room temperature measurement

Adjusting room temperature readings by compensating for probe differences.

CF03 - Choosing the operating mode

Selecting the regulation mode: On/Off, Proportional-Integral (PI) for radiators or floor.

CF09 - Association with receiver(s)

Pairing the transmitter with the receiver unit via button presses and display confirmation.

CF10 - Radio test

Testing radio communication by sending frames and checking receiver LED response.

Basic Operations

Setting the temperatures (set-points)

Adjusting target temperatures for Frost Protection, Heat, Economy, and Comfort modes.

Advanced Modes and Programming

Programming

Creating daily heating/cooling schedules by defining time slots and temperature profiles.

Absence mode

Setting a specific temperature for a defined period of absence (1-365 days).

Product Information and Support

Help

Troubleshooting common issues such as no display, incorrect temperature, or receiver not responding.