the product you have purchased is an axial extractor fan for exhausting directly outside through short lengths of ducting and is
suitable for wall or ceiling installation. To ensure optimum operation and guarantee a long life, please read this manual carefully that
explains how to effectuate a correct installation and to use and maintain the product properly. Following all the instructions ensures
reliability and long life, both mechanically and electrically.
The manufacturer declines any responsibility for damages caused to persons or things deriving from the lack of observ-
ance of the following described instructions.
The product is constructed using state of the art technology and respects the standards in force regarding electrical equipment. It
conforms with the EMC European Directive in force regarding radio interference suppression and electro-magnetic compatibility.
Installation and usage instructions
WARNING: Serious injury or death can be caused if these instructions are
not applied!
Do not use this product for uses that are different from those for which it has been de-
signed.
-



recycling norms in force in your country.



This appliance can be used by children aged from 8 years and above and persons with
-
ge if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without su-
pervision.
The means of disconnection from the supply mains must have a contact separation
in all poles and must provide full disconnection under overvoltage category III condi-
tions.





-
stances and vapours, such as alcohol, insecticides, petrol, etc.
The product can be connected to the supply mains only if the voltage and the frequency
of the supply mains correspond to those written in the rating label.
In the case of malfunction, anomaly or any type of fault disconnect the appliance from

for repairs.

norms in force regarding electrical systems.

-
ation of fumes coming from the combustion of stoves or other combustion devices. It
must discharge directly outside the building.
9
10
11
MAINTENANCE
elicent
OFF
ON
TROUBLESHOOTING
DISMANTLING AND RECYCLING
    

of old products in normal domestic waste material.
100 EC 2V
EN
In case of incorrect or doubtful translation, only the Italian text applies (Translation of the original instructions).
Maico Italia S.p.A.

Tel +39 030 9913575 Fax +39 030 9913766
e-mail: info@maico-italia.it www.maico-italia.it
Maximum speed selection

Adjusting humidity thresholds and timers
To adjust the humidistat and timer trimmers, remove the front cover of the fan to access the trimmers.

a higher level of relative humidity.

to decrease it.
Activation / Deactivation DELAY ON-TIMER


Jumper DELAY-ON TIMER
 Disable
Jumper 3 Enable
TM
HY
N
L
X 1
2 3
TM
HY
N
L
X 1
2 3
TM
HY
N
L
X 1
2 3
PROBLEM CAUSE AND REMEDY
The appliance does not switch on There is no voltage.

The impeller does not turn 
TM
HY
N
L
X 1
2 3
TM
HY
N
L
X 1
2 3
TM
HY
N
L
X 1
2 3
Jumper Low speed setting
Jumper 1 
Jumper 2 
Question and Answer IconNeed help?

Do you have a question about the Elicent ELEGANCE 100 EC 2V and is the answer not in the manual?

Overview

This document describes the Elegance 100 EC 2V, an exhaust fan designed for bathroom and kitchen use.

Function Description

The Elegance 100 EC 2V is a continuous running fan with energy-saving and efficiency features. It operates quietly and includes a 3-speed fan. The device is designed to maintain humidity levels between 40% and 90% and can be adjusted to compensate for humidity variations. It also features a delay-off timer and a boost speed for maximum performance when required via an external switch.

The fan offers two versions:

  • Version Elegance 100 EC 2V DT: This version is equipped with 3 speeds and operates continuously, choosing between 2 pre-selectable speeds (using a jumper) to maintain humidity levels. The fan automatically adjusts its speed based on humidity changes. An external switch can activate the boost speed. The delay-off timer allows the fan to continue running for a set period after the switch is turned off.
  • Version Elegance 100 EC 2V: This version is a 3-speed, continuous running fan with selectable delay-on timer (delay on boost of 2 minutes) and humidity adjustment. It automatically adjusts its speed to maintain humidity levels. The boost speed can also be activated by an external switch.

Important Technical Specifications

  • Airflow: The fan is capable of moving air at a rate of 98.2 mm.
  • Duct Diameter: The fan is designed for a 6 mm duct.
  • Humidity Control: The device aims to maintain relative humidity between 40% and 90% (+/-5% tolerance).
  • Delay-off Timer: The delay-off timer can be set between 2 and 30 minutes.
  • Delay-on Timer: The delay-on timer for the boost function is 2 minutes.
  • Operating Temperature: The device is designed to operate in environmental temperatures between 40°C.

Usage Features

  • Continuous Running: The fan operates continuously to maintain optimal air quality and humidity levels.
  • Automatic Humidity Adjustment: The fan automatically adjusts its speed based on the detected humidity levels to maintain a comfortable environment.
  • Boost Speed: An external switch can activate a boost speed for maximum performance when rapid ventilation is needed, such as after showering or cooking.
  • Delay-off Timer: The delay-off timer allows the fan to continue running for a set period after the external switch is turned off, ensuring complete removal of moisture or odors.
  • Delay-on Timer: The delay-on timer for the boost function prevents the fan from immediately switching to boost speed, allowing for a brief period of normal operation before increasing speed.
  • Pre-selectable Speeds: Users can choose between two pre-selectable speeds using a jumper, allowing for customization based on specific ventilation needs.
  • Quiet Operation: The fan is designed for quiet operation, minimizing disturbance.
  • Installation: The fan can be installed in various locations, including walls and ceilings. It is recommended to install the fan with a slight downward slope to facilitate condensation drainage.
  • Wiring Diagrams: The manual provides detailed wiring diagrams for different configurations, including H03 VV-F and H03 VVH2-F.
  • Maintenance: The fan is designed for easy maintenance, with removable components for cleaning.

Maintenance Features

  • Cleaning: Regular cleaning of the fan and its components is essential to maintain optimal performance and prevent the accumulation of dust and debris.
  • Disconnection: Always disconnect the device from the power supply before performing any maintenance or cleaning.
  • Component Removal: The fan's components, such as the grille and impeller, can be easily removed for cleaning.
  • Duct Cleaning: Periodically check and clean the ductwork to ensure proper airflow and prevent blockages.
  • Professional Servicing: If the device experiences any malfunctions or requires extensive repairs, it is recommended to contact a qualified professional or the manufacturer's service center.
  • Chemicals: Do not use abrasive cleaners, solvents, or corrosive chemicals, as they can damage the device. Use a soft cloth and mild detergent for cleaning.
  • Water: Do not immerse the appliance in water or other liquids.
  • Environmental Conditions: Do not expose the product to environmental temperatures more than 40°C.
  • Airflow Obstruction: Do not obstruct the air inlet and outlet of the appliance in any way whatsoever. When using air ducting, make sure that the ducting is not blocked.
  • Minimum Height: It is recommended to install the appliance at a minimum height of 2.30 meters from the floor.
  • Air Recirculation: For an optimum functioning of the appliance, it is necessary to ensure an adequate recirculation of air in the room. Consult the local norms with regards to this.
  • Manual Reset Protection System: This equipment is fitted with a manual reset protection system. When the mechanical impediment that prevents rotation will kick in and stop the motor. To resume normal operations, please proceed as follows:
    • Disconnect the equipment from the power supply.
    • Remove the cause of the mechanical impediment (qualified personnel only).
    • Reconnect the equipment to the power supply.
    • The equipment will resume normal functioning only if no additional anomalies are detected by the protection system. Should the problem persist, please contact the service center.

This manual emphasizes the importance of safety and proper installation to ensure the longevity and efficient operation of the Elegance 100 EC 2V. It also highlights the need for regular maintenance and adherence to local regulations for optimal performance.