Smart ZB Thermostat 16 A
Sensors settings
Temperature Detection
Active Brightness Level
Screen Active Duration
Floor Sensor Type
Idle Brightness Level
Air Temperature
1 Min(s) 0 Sec(s)
-- K
100%
Screen Brightness Settings
Sensors Settings
Settings
Temperature Calibration
-9.0 C
?
?
Valve Protection
Valve Protection Settings
Child Lock
Child Protection Settings
100%
Temperature Detection
Floor Temperature
Max Guard Temperature
30 C
Temperature Calibration
0.0 C?
Min Guard Temperature
10 C
A
B
D
C
E
Temperature detection
You can check the sensor type (A) under temperature detection, based on your
preset.
Air Temperature: for preset P1 to P6.
Floor Temperature: for preset P7 to P8.
NOTE: Sensor settings are not available for regulator mode (P9).
Temperature calibration
To set the temperature calibration:
1. Tap Temperature Calibration (B) for a slide-up menu.
2. Drag the sliding bar or use –/+ button to set the temperature calibration.
NOTE: The temperature calibration ranges from -9°C to +9°C and can be
adjusted in 0.1°C increments.
3. Tap Save.
Floor sensor type
To select the floor sensor type:
1. Tap Floor Sensor Type (C) for slide up menu.
2. Select the sensor type (kOhm) form the following list.
10K
12K
15K
33K
47K
NOTE: Select correct floor sensor type which is installed and then you
can set calibration and guard temperature.