Smart ZB Thermostat 16 A
LED Indications
Pairing the device
Status User Interaction Description
Pairing in progress
The thermostat matrix display flashes "Jn"
to indicate joining is initiated when the
thermostat O touch button is pressed and
held for > 3 s.
Successful joining network The thermostat matrix display flashes a
green
LED when the thermostat
successfully joins a network.
Fails to join the network The thermostat matrix display flashes a red
LED when the thermostat fails to join
the network.
Presetting the device
Status User Interaction Description
Enter preset selection
By default, thermostat matrix display flashes
“P5” if there is no external sensor
connected, or “P8” if there is any external
sensor connected when the thermostat is
first powered on or after a factory reset.
Modify preset selection
The default preset value can be modified by
simultaneously pressing "O" and "+" for 2 s
to enter advanced settings menu In
advance setting menu the thermostat matrix
display flashes "P1" or "P2...P9" when +/–
button is pressed.
Note: When + button is pressed, preset
increases by one; similarly, the preset
decreases by one when the – button is
pressed.
For more information, refer to the section
presetting the device, page 7.
Setting a sensor type
Status User Interaction Description
Floor sensor type selection
The thermostat matrix display the floor
sensor type and
LED flashes blue.
DUG_ZB Thermostat 16 A_ELKO-00 41