18
PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM
P10 – All control boards remain OFF; mixing augers do not
turn; lights inside the tank lids remain OFF. Only
compressor and condenser fan motor work.
Problem
The electronic boards are not powered.
Reason_1
Transformer or transformer fuse is burned, due to power surges or other accidental reasons.
Solution_1
Replace the 5Amp fuse (pos.88): remove the fuse holder; remove the old fuse; insert the new
one; insert the fuse holder back into its place. If machine still does not come on, check with a
tester 12V reading past transformer, at the output terminals of the transformer; if there is no
12 Volts coming out of the transformer, replace it.