PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM
P12 – Control board’s screen is blinking. After pressing and
releasing MENU button "ALARM LEVEL" comes on the
screen. Machine works properly.
Problem
Machine alerts an operator about low level of MIX in a hopper.
Reason_1
If tank is full of MIX (at least 8 liters/2 gallons) the level probe (pos. 15) is not in a proper
contact with a terminal (pos.37).
Solution_1
Restore probe level’s contact inside the terminal (pos 37). Also, make sure the probe is located
in the correct spot on the back of the tank – picture above.