5
PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM
P01 – Machine does not freeze and red light located near
the main power switch (pos.72) is ON
Problem
High pressure switch cut off compressor (pos.87).
93
Reason_1
Condenser/Condenser air filter is dirty (pos.95).
Solution_1
Clean the condenser/condenser air filter with a brush (a) or compressed air and them reset the
compressor by pressing high pressure switch down (pos.93). ATTENTION: machine has to be
ON in order to reset the compressor.
Reason_2
Airflow around the machine is insufficient due to either other piece of equipment blowing hot
air into the machine or insufficient space (recommended approximately 12 cm – 5 inches on
each side).