9
PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM
P03 – In SLUSH mode machine does not freeze and
solenoid light does not come ON on the control board’s
screen; In COLD/DEFROST mode machine works properly
Problem
Machine does not freeze.
Reason_1
Control Board is discalibrated.
Solution_1
Turn the machine OFF (pos.69); fill up the machine with 1 gallon of tap water at 65-75
degrees F; Turn the machine back ON; set to SLUSH mode; auto calibration process begins
(WAIT AUTO SETTING comes on the control board’s screen in place of SLUSH); After approx.
30 seconds calibration process ends and machine goes into SLUSH mode.