EasyManua.ls Logo

ELMETRON CX-401 User Manual

ELMETRON CX-401
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
WATERPROOF
MULTIFUNCTION
METER
CX-401
USER‘S MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ELMETRON CX-401 and is the answer not in the manual?

ELMETRON CX-401 Specifications

General IconGeneral
BrandELMETRON
ModelCX-401
CategoryMeasuring Instruments
LanguageEnglish

Summary

Introduction

Exploitation Notices

Important notices regarding the proper use and potential issues with the meter and its electrodes.

Characteristics of the Meter

Detailed features and capabilities of the CX-401 multifunction meter.

Meter Applications

Outlines the industries and specific applications for which the CX-401 meter is designed.

Outside View and Display

Description of the meter's front panel, LCD display, and various symbols shown.

Switching the Meter On and Off

Instructions for powering the meter on and off, including auto-switch off function.

Preparation and Setup

Preparation to Work

Steps to prepare the meter and connect sensors before starting measurements.

Temperature Compensation Modes

Explanation of how to select between automatic and manual temperature compensation modes.

Measurement Resolution Adjustment

How to adjust the display resolution for different measurement types (pH, conductivity, O2, mV).

Stabilised Reading Signalisation

How to enable or disable the signalisation of a stabilised reading (READY symbol).

Electrode Management

How to select and manage different calibrated electrode characteristics stored in the meter.

Calibration Validity Settings

How to set a validity period for calibration and receive expiry notifications.

Button Function Customization

Customizing the MEM button to record readings, start series, or hold display.

Holding Displayed Readings

How to freeze the current measurement value on the display using the HOLD function.

pH Measurement

pH Electrode Preparation

Detailed instructions for preparing and maintaining the pH electrode for optimal performance.

pH Measurement Calibration

General information and importance of calibrating the electrode for accurate measurements.

pH Measurement Procedures

Steps for performing pH measurements using automatic and manual temperature compensation.

Interpreting pH Results

Discussion of temperature compensation's impact on pH measurements and how to interpret results.

Conductivity and Salinity Measurement

Basics of Conductivity Measurement

Fundamentals of conductivity measurement, including factors affecting it like temperature and salinity.

Conductivity Measurement Parameters

Setting units, coefficients, and reference temperature for conductivity measurements.

Conductivity Cell Maintenance

Proper care and cleaning procedures for the conductivity cell to ensure accuracy.

Conductivity Measurement Calibration

Overview of conductivity cell calibration, including K constant importance and methods.

Conductivity Measurement Operations

Procedures for performing conductivity measurements with different temperature compensation methods.

Salinity and TDS Measurement

Measuring salinity and Total Dissolved Solids by converting conductivity readings.

Temperature Compensation Notices

Specific temperature compensation considerations for natural and ultra pure water measurements.

Determining the Alpha Coefficient

Provides a method to determine the α coefficient for temperature compensation in conductivity measurements.

Oxygen Concentration Measurement

Oxygen Measurement Basics

Introduction to dissolved oxygen measurement using the oxygen sensor and its basic principles.

Oxygen Measurement Parameters

Setting units and salinity compensation for oxygen concentration measurements.

Dissolved Oxygen Measurement

Procedures for measuring dissolved oxygen concentration in water, considering various factors.

Oxygen Saturation in Air Measurement

Procedure for measuring oxygen saturation levels directly in ambient air.

Atmospheric Pressure Measurement

Performing Atmospheric Pressure Measurement

How to perform and read atmospheric pressure measurements using the meter.

Redox Potential and Temperature Measurement

Redox Measurement Setup

Choosing measurement modes (absolute/relative) and setting reference potential for redox readings.

Redox Potential Measurement

Instructions for performing redox potential measurements using the meter.

Temperature Measurement

Procedure for measuring temperature using the connected Pt-1000 probe.

Other Functions

Clock and Date Settings

Managing the meter's internal clock, date, and auto-switch off functions.

Storing and Reading Results

Methods for saving, retrieving, and managing measurement data stored in the meter's memory.

Calibration Reporting

How the meter generates, stores, and allows transfer of calibration reports.

PC Connectivity

Instructions for connecting the meter to a computer for data transfer and analysis via USB.

Power and Technical Details

Power and Battery Management

Information on power sources, charging, and replacing the meter's batteries.

Technical Specifications

Detailed technical specifications for all measurement functions, ranges, and accuracies.

Equipment List

Lists the standard and additional equipment included or available for the meter.

Warranty Information

Details of the product warranty terms and conditions.

Related product manuals