30
Regularly check non-return valves at
[11] and [12] for function. If they
are not functioning correctly, there is
risk that water will enter the air
supply network.
If water and/or compressed air flows
out of the excess pressure valve
[13] down into the box, this means
that the non-return valve [12] on
the distribution pipe is letting by. In
this case, replace or repair the non-
return valve [12], and install a new
seat, valve and spring.
If the venturi is letting sufficient
water through but is not suctioning
anything up, the restrictor plate in
the suction grommet must be
checked for blockage. Disassembly:
unscrew the connector from the
intake house, note: the restrictor
plate is mounted here, clean the hole
in this plate, reinstall the parts, note:
tighten the connector firmly.
If water is leaking into the chemical
jerry can, the non-return valve in the
injector [14] and [15] are polluted
or damaged, unscrew the injector out
of the block than dissemble injector
as shown in drawing [16], clean seat
and ball and if both not damaged
mount the non return valve in
reverse order and screw into block (
first grease the thread with food
grease), if damaged replace complete
chemical non return-valve.
Regularly check the nozzles, hoses
and spray guns for cracks and
functioning.
13
15
14
12
11
16

Table of Contents