68 BA-en-3041-2008_PC
53 Yes Range
PID controller
• Clear the error.
• If this error occurs again, send in the device
for repairs.
54 Yes Setpoint ramp
• Clear the error.
• If this error occurs again, send in the device
for repairs.
55 Yes Flash count of hard
flashes, limit excee-
ded
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
• Clear the error.
• If this error occurs again, send in the device
for repairs.
56 Yes Flash count of soft
flashes,
limit exceeded
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
• Clear the error.
• If this error occurs again, send in the device
for repairs.
57 Yes Temperature
• Check the installation of the generator.
• Improve the cooling of the housing.
• Reduce the ambient temperature.
• Reduce the setpoint value.
• Clear the error.
• If this error occurs again, send in the device
for repairs.
58 Yes High voltage
Discharge
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
• Clear the error.
• If this error occurs again, send in the device
for repairs.
59 Yes Current
High voltage
Discharge
• Clean the bar.
• Check the mounting position.
• Reduce the setpoint value.
• Clear the error.
• If this error occurs again, send in the device
for repairs.
Error
number
Error
clearable
Cause Measure