SBC session border controllers 103
The syslog parameters configure the IP address of the syslog server, the UDP port on which the syslog server
receives messages.
Enable enable event logging;
Remote logging when checked, the log will be saved on the server whose IP address is set below,
otherwise the log will be saved to RAM (the size of the log is limited to 5 MB, in addition, log entries are
saved only until you reboot the device). Saving the log to RAM is not recommended for use.
Server IP-address server address to save the event log;
Server Port the server port to save the event log;
The «Start» and «Stop» buttons allow you to start and stop the log transfer to the server respectively.
Working with objects and 'Objects' menu
In addition to create, edit and remove icons, you may use the
corresponding 'Objects' menu items to perform different operations with
objects.
Saving configuration and 'Service' menu
To discard all changes, select «Service»—«Discard all changes» menu.
To write the current configuration into non-volatile memory of the
the device, select «Service»—«Save configuration into flash» menu.
To restart the device software, select «Service»—«Restart software»
menu.
To restart the device completely, select «Service»—«Restart device»
menu.
To perform forced time re-synchronization with NTP server, select
«Service»—«Restart NTP client» menu.
To generate and save logs on the device, select the «Service»—«Save logs to file» menu. The archive with
logs can be found under PCAP traces files and folders in the tracing directory.
An example of the name of the archive:
sbc_logs_current_calls_20201111_165508.tar.gz
To forcibly restart the SSHD, select the menu «Service» - «Restart SSHD
1
».
To read/write the main device configuration file, select the «Service» - «Configuration files management»
menu.
To reset the device configuration, select the menu «Service» - «Configuration files management» and press
the «Reset» button. This will reset all settings except for network parameters, network interfaces, network routes,
firewall profiles and rules, white list and time server (NTP). For a complete factory reset, refer to the section 2.6.
To configure the device local date and time manually, select the «Service» - «Set date/time» menu; see
Section 4.1.13 Time and date configuration.
To update the software via the web interface, select the menu «Service» - «Firmware upgrade», see Section
4.1.14 Firmware update via web interface.
To update/add licenses, select «Service»—«License update» menu; see Section 4.1.15 Licenses.