136 SBC session border controllers
Enter the QoS parameter configuration mode
Terminate this CLI session
Save mirroring settings without applying
Save VLAN settings without applying
GE_PORT1(1)/
GE_PORT2(2)/
CPU(4)/
SFP0(6)/
SFP1(7)
src_in/
src_out/
dst_in/
dst_out
on/off
Configure port mirroring:
PORT — port type;
NAME — port designation:
- src_in — incoming packet source port — copy
frames received from this port (source port);
- src_out — outgoing packet source port — copy
frames transmitted by this port (source port);
- dst_in — incoming packet destination port —
receiver port for the copied frames received by the
selected source ports;
- dst_out — outgoing packet destination port —
receiver port for the copied frames transmitted by
the selected source ports;
<ON_OFF>
<B_MASTER>
B_SLAVE
GE_PORT0/GE_PORT1/
GE_PORT2/SFP0/SFP1
GE_PORT0/GE_PORT1/
GE_PORT2/SFP0/SFP1
Enable Dual Homing redundancy
B_MASTER — main port
B_SLAVE — redundant port
PREEMPTION — enable/disable return to the main
port when it is restored
GE_PORT1(1)/
GE_PORT2(2)/
CPU(4)/
SFP0(6)/
SFP1(7)
0-4095
Assign VLAN ID to this port.
GE_PORT1(1)/
GE_PORT2(2)/
CPU(4)/
SFP0(6)/
SFP1(7)
unmodified/
untagged/
tagged/
double-tag
Set the packet transmission mode on this port.
EGRESS – packet transmission mode:
– unmodified — packets are transmitted by this
port unchanged (i.e. in the same form as they
came to the other port of the switch);
– untagged — packets will always be sent
without VLAN tag by this port;
– tagged — packets will always be sent with
VLAN tag by this port;
– Double tag — each packet will be sent with
two VLAN tags — if received packet was
tagged and came with one VLAN tag — if the
received packet was untagged.
Set the received tagged packet control mode for this
port.