SBC session border controllers 45
Monitoring > Front-ports
Link the status of the cable connection on the port (UP/DOWN);
Speed committed rate on the port;
Duplex data transmission mode (half-full-duplex);
LACP group the LACP channel the port is included in and its status (UP/DOWN)
LACP state the mode in which the port is operating (active/backup)
RX Bytes a storage counter of received bytes, including the different types of received packets;
TX Bytes a storage counter of transmitted bytes, including the different types of transmitted packets.
4.1.2.5 Alarm events list
When an alarm occurs, information about it is displayed in the header of the Web Configurator. If there are
several active alarms, the web configurator header will display the most critical one at the time.
When there are no alarms, the message «No alarms» will be shown.
In the Alarm events list menu, the list of alarm events, ranked by date and time is displayed. There is also the
"Clear" button that removes all information messages and resolved alarms from the current list.
Monitoring Alarm events list
Alarm table
alarm sequence number;
Time alarm occurrence time in HH:MM:SS format;
Date alarm occurrence date in DD/MM/YY format;
Type alarm types are given in Table 18.