SMG digital gateway 85
No.the sequence number of the SS-7 timer profile.
Profileprofile name.
SS7 Linkseta list of SS-7 line groups which have this profile selected.
Profile Settings
Names of MTP2 level timers and their default settings are described in Q.703 ITU-T recommendation,
§12.3 Timers.
Name
Default Value, seconds
Range, seconds
T1
50
40 50
T2
50
5 150
T3
2
1 2
T4n
8.2
7.5 9.5
T4e
0.5
0.4 0.6
T6
6
3 6
T7n
2
0.5 2
Names of MTP3 level timers and their default settings are described in Q.704 ITU-T recommendation,
§16.8 Timers and Timer Values.
Name
Default Value, seconds
Range, seconds
T2
2
0.7 2
T4
1.2
0.5 1.2
T12
1.5
0.8 1.5
T13
1.5
0.8 1.5
T14
3
2 3
T17
1.5
0.8 1.5
T22
180
180 360
T23
180
180 360