Universal Network Terminal TAU-72.IP/TAU-36.IP 131
The Run test button, located against each port, allows to test the subscriber line associated with
this port. When the button is pressed, the test will be executed (it may take up to one minute.) To see the
results when the test finishes, hover the mouse cursor over the 'result' link located against the respective
port, or open the test results window by clicking the link:
Common resulttest result status;
Foreign DC voltage В (RING), Vforeign voltage in В wire (RING), V;
Foreign DC voltage A (TIP), Vforeign voltage in A wire (TIP), V;
Line supply voltage, Vline power supply voltage, V;
Ringing voltage, Vcall voltage, V;
Resist A (TIP)B (RING), kOmresistance between А (TIP) and В (RING) wires, kΩ;
Resist A (TIP)-GND, kOmresistance between А (TIP) wire and ground GND, kΩ;
Resist B (RING)-GND, kOmresistance between B (RING) wire and ground GND, kΩ;
Capacity A (TIP)B (RING), mkFcapacity between А (TIP) and В (RING) wires, µF;
Capacity A (TIP)-GND, mkFcapacity between А (TIP) wire and ground GND, µF;
Capacity B (RING)-GND, mkFcapacity between B (RING) wire and ground GND, µF;
Phone is connected-connected phone indication.
Do not launch the test for multiple ports simultaneously. Port test cannot be interrupted!
Test results description:
OKline test has been completed successfully;
TEST FAILUREinvalid operand values were calculated during measurement. For example, division by zero
has occurred. This error may appear in line resistance and capacity measurements upon the expiry of
capacity measurement timeout;
STATE FAILUREoccurs when the set detects leakage current, and during test, when the current line wire
mismatches the required state;
RESISTANCE NOT MEASUREDmeans that during the line resistance measurement one of the values was
lower than the minimum allowed value (100Ω) As a rule, this error may be caused by a wire or ground short
circuit;