N Parameter Min. Default Max Notes
47 1 Memory Num. 0 0 99999999
Quick call number associated with the button “
”.
0 = disabled
48 2 Memory Num. 0 0 99999999
Quick call number associated with the button “
”.
0 = disabled
49 Ext.1 Address 0 0 99999999 Address of external transponder reading device 1
50 Ext.2 Address 0 0 99999999 Address of external transponder reading device 2
51 Ext.3 Address 0 0 99999999 Address of external transponder reading device 3
52 Ext.4 Address 0 0 99999999 Address of external transponder reading device 4
53 Ext.5 Address 0 0 99999999 Address of external transponder reading device 5
54 Ext.6 Address 0 0 99999999 Address of external transponder reading device 6
55 Ext.7 Address 0 0 99999999 Address of external transponder reading device 7
56 Ext.8 Address 0 0 99999999 Address of external transponder reading device 8
57 Tx Key 0030 = does not transmit the key;
1 = transmits the key if it is in the entrance panel database
2 = transmits the key if it is not in the entrance panel database
3 = always transmits the key
58 Request Passw 0011 = requests password confirmation from the transponder reading
device
59 Tx UP / Down 0110 = transmits the key on interphone cable riser serial line (UP)
1 = transmits the key to the main entrance panel / switchboard (DOWN)
60 Hidden Paras 0 0 50 Typing 27 enables the display and programming of parameters 61 –
67
61 Mon. Off Time 0 30 1000 Monitor power-off timeout.
The programmed value is multiplied by 10ms, therefore if Mon. Off
Time = 30 then the timeout = 300ms
62 Transit Time 0 5 1000 Maximum transit time in minutes
63 Command Rep.(+) 0 388 65535 Repetition of special commands
64 Restart Time(h) 0 0 99999999 NOT USED
65 Factory reset. 0 0 99999999 Typing the code 31830988 resets the parameters to their default
values.
66 Flash sector reset 0 0 26 Erases the flash sector indicated from 1 to 26.
IMPORTANT! Improper use of this parameter can damage the en-
trance panel or cause malfunctions!
67 Number of keys from keypad 0 100 2000 Maximum number of keys insertable from keypad
If the parameter is 0, the keys from keypad are disabled.
EN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elvox 1282 and is the answer not in the manual?

Elvox 1282 Specifications

General IconGeneral
BrandElvox
Model1282
CategoryIntercom System
LanguageEnglish

Related product manuals