30
L
P
J1
C
R1
R2
4
4
S1 15 0
PRI
F2CH S F1 435
CNONOC
1234554321
5341
+L
M1
V2
+I
SR
V1
VL
F1
4
F2
CH
V
3
1
M
5
8
6
4
*
88888888
8
7
R
0
4
1
2
5
9
C
3
6
WIRING DIAGRAM
The buttons "F1" and activate the function F1. The buttons "F2" and activate function F2.
Power supply
Art. 6941
Relay
Art. 170/001
Relay
Art. 170/001
C- Entrance panel Art. 1284
CX- Entrance panel series 1200
VARIANTS si085
During programming of the entrance panel it is possible to change the following two parameters:
22 T_F1 Function time F1 Activation time of 1st auxiliary function F1
23 T_F2 Function time F2 Activation time of 2nd auxiliary function F2
Connection of auxiliary functions F1 - F2 in systems equipped with internal decoding or without internal decoding.
In some cases, enabling the functions requires the use of supplementary buttons and connections to be made in addition to the
basic connections. Interphones type 6204 and 6201 are fitted as standard with only the lock release button; for the use of a sec-
ond auxiliary function, it is necessary to add button art. 6152 (pack containing 8 N.O. push-button in intephones type 6201 and type
6C59 (pair of N.O. push-buttons) in interphones type 6204. It is possible to activate an auxiliary function F1 controlled by the inter-
phones or monitors by connecting a relay Art. 170/001 as shown in the diagram (terminals R1-4 of the power supply). It is possi-
ble to activate an auxiliary function F2 controlled by the interphones or monitors by connecting a relay Art. 170/001 as shown in
the diagram (terminals R2-4 of the power supply unit).
Connection of
relays for addi-
tional functions
INTERPHONE
CABLE RISER
Mains
Additional function
F1
Additional function
F2
CX
1435
5431
5
12
6
11
1
4
3
3
5
6
4
1
3
5
6
4
1
V3
13
V1
11
12
M
8
9
6
7
3
4
1
2
5
10
1
7
6
C1
4
C3
3
SR
D
D1
D3
1
2
4
5
3
C
3451
45312A1
4
A3
1
6
7
3
453
B
12
B1
B3
2
1
5
4
3
A
SR
C
A
6
3451
6
A
C
SD SD
A
A- Distributor 949B
Phone
Art. 8877
Phone
Art. 6201
Interphones with internal coding
Interphones without
internal coding
INTERPHONE
CABLE RISER
TO POWER SUPPLY
ART. 6948
TO POWER SUPPLY
ART. 6948
INTERPHONE
CABLE RISER
Phone
Art. 6201
Phone
Art. 887B
Art. 887B/1
Phone
Art. 6204
Phone
Art. 887B
Art. 887B/1
Phone
Art. 6604/AU
Art. 6704/AU
Phone
Art. 8877